High Voltage Laboratory | Test Facilities

  • Contact

UHV AC Test Hall / AC 1650kV High Voltage Source /
DC 500kV High Voltage Source / Corona Noise Instrument

Power-frequency withstand voltage test on 1000kV gas bushing

Power-frequency withstand voltage test on 1000kV gas bushing

Outline of Test Facilities

Main Facilities Outline
UHV AC Test Hall Dimensions of hall:40m x 40m x 30m h.
Double-shielding system by expanded iron netting(Electromagnetic shielding effect:75dB at 1MHz)
Auxiliary equipment:AC high voltage transformers, 2m diam. shape gap, Spray nozzle set, 3mf x 5mh. oil tank
AC 1650kV High Voltage Source Transformers:550kV, 500kVA, 3 units in cascade connection, corona free up to 1000kV, with reactor for compensating capacitive load.
Power source:400kVA synchronous generator.
DC 500kV High Voltage Source Type:Delon-Greinacher circuit by using silicone rectifiers.
Rated voltage:500kV.
Rated current:30mA.
Corona Noise Instrument Coupling capacitors:2000pF(500kV), 1000pF(1000kV)
Radio noise meters:NEMA type meter, CISPR type meter.
Partial discharge measuring instruments:ERA III type, ERA-803 type.